+86-28-82633987sales@biopurify.com
cnen
  • iso9001 iso9001
  • iso17025 iso17025
  • usp usp
Alternate Text
Home > Literature List > Combination of multi-model statistical analysis and quantitative fingerprinting in quality evaluation of Shuang-huang-lian oral liquid

Combination of multi-model statistical analysis and quantitative fingerprinting in quality evaluation of Shuang-huang-lian oral liquid

Journal name:Analytical and Bioanalytical Chemistry
Literature No.:
Literature Url: https://link.springer.com/article/10.1007/s00216-020-02841-z
Date publication:18 August 2020
Abstract

A model consisting of quantitative fingerprinting integrated with fundamental statistical analysis was established to carry out quality control analysis of Shuang-huang-lian (SHL) oral liquid. The quantitative fingerprinting approach was developed by systematic investigation of the chromatographic condition and optimization of a gradient using a complex sample analysis software system (CSASS). Five pivotal components from three traditional Chinese medicines of SHL oral liquid were determined at dual wavelengths, including phillyrin, baicalin, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid. Among them, neochlorogenic acid and cryptochlorogenic acid were quantified by quantitative analysis of multi-components with a single marker (QAMS) method. Further, the developed quantitative fingerprinting approach was validated. Good linearity with correlation coefficients (R2) higher than 0.9999 were achieved for phillyrin, baicalin and chlorogenic acid. Recoveries of the three analytes were between 96% and 108%. Relative standard deviation (RSD) values were below 3% regarding the stability and intra-day and inter-day precision. Besides, the feasibility of the QAMS method was verified by an external standard method (ESM) using 18 batches of SHL oral liquid. Fifty-nine batches of SHL oral liquid from nine manufacturers were then analyzed. Effective distinction was realized based on a linear principal component analysis (linear-PCA) model by the combination of the quantitative data and chromatographic fingerprinting. The linear-PCA model based on quantitative chromatographic fingerprinting exhibited great advantage over conventional similarity analysis to distinguish between different samples. The strategy provided a particularly simple and effective approach for quality evaluation of SHL oral liquid from various manufacturers.


… acid (88.9%), neochlorogenic acid (99.4%), wogonin, wogonoside, oroxylin
A, isochlorogenic acid A
, isochlorogenic acid B, isochlorogenic acid C,
lonicerin, rutin, forsythoside A, phillygenin and betulinic acid were obtained from Biopurify